Home > Failed To > Wmi Repository Is Inconsistent

Wmi Repository Is Inconsistent

Contents

You receive a different WMI result set from the collector debug vs WBETEST, or an error from one and not the other. You run a script on client Computer A, which connects to Print Server B. Call 888-415-6442, +1 (805) 617-3884 or Contact Us. Likewise, some WMI data providers, such as the SNMP Provider, are either not available in all operating systems or are not part of the default installation of WMI.

You can find it in Microsoft's download center (or search Microsoft's website for "WMIDiag", should the download ID have been altered in the meantime). If it does not, then simply make Repository_good the WMI Repository once more.Why would you do something like this? For more information on delegation and remote connections, see Connecting to a 3rd Computer-Delegation (http://msdn.microsoft.com/library/default.asp?url=/library/en-us/wmisdk/wmi/connecting_to_a_3rd_computer-delegation.asp) and Securing a Remote WMI Connection (http://msdn.microsoft.com/library/en-us/wmisdk/wmi/securing_a_remote_wmi_connection.asp). With this setup you will not be able to connect to a remote computer running Windows Server 2003. recommended you read

Wmi Repository Is Inconsistent

Windows 7:  Low-integrity users have read-only permissions for local WMI operations. Specifically, any remote access to the server using an administrator security token is automatically elevated with full administrator rights, including access to the root folder. For a list of the standard WMI providers, see “WMI Providers” under the WMI Reference section. The WMI diag option A very good start to approaching WMI problems is the use of Microsoft's very own diagnosis tool, WMIDiag, of course.

This documentation is archived and is not being maintained. Here is the corrected version: @echo off sc config winmgmt start= disabled net stop winmgmt /y %systemdrive% cd %windir%system32wbem for /f %%s in ('dir /b *.dll') do regsvr32 /s %%s wmiprvse For more information, see Invoking an Asynchronous Query (http://msdn.microsoft.com/library/en-us/wmisdk/wmi/invoking_an_asynchronous_query.asp) and Setting Security on an Asynchronous Call (http://msdn.microsoft.com/library/default.asp?url=/library/en-us/wmisdk/wmi/setting_security_on_an_asynchronous_call.asp). Failed To Connect To Wmi Namespace Root Cimv2 For example, the Win32_PingStatus class defined by the Ping provider is unlikely to be made available for Windows 2000.

Output from all batch operations is written to a desktop log file, Repair_WMI.txt, which can be searched for the word "error" to verify success or failure of all operations. In that case its usually enough to wait a few minutes until all the dependant services finished exiting and then to run the command Winmgmt /resetrepository again, this time it should For example, you try to connect to a class named Win32_Services (with an s on the end) when the actual class name is Win32_Service (without an s on the end).You reference Add comment Created on Oct 1, 2012 2:53:43 PM by Marcel Wiechmann (0) ●1 ●1 Permalink Votes:0 Your Vote: Up Down Having worked through a few of the suggested fixes above,

The WMI Software Developers Kit (SDK) For a set of problem solutions by category, see Using WMI > WMI Tasks for Scripts and Applications.http://www.microsoft.com/msdownload/platformsdk/sdkupdate  The Windows 2000 Scripting Guide onlineThe complete Wmi Diagnosis Utility On pre-Windows 2000 systems, the Performance Monitoring Provider must be used to obtain performance counters using WMI. If you try to access that class on, say, a computer running Windows 2000 you will probably get an “Invalid Class” error.Note. but now wmi option to restart,start and stop are disabled. 4 years ago Reply thomas Team, We have pushed the SCCM patches for windows 2008r2,2003 servers.

Wmi Remote Access Denied

somewhere in "C:Program Files" (which is actually the case on my system). For more information, please see this page. Wmi Repository Is Inconsistent A better approach would have the script prompt you for the password each time it runs. Failed To Initialize All Required Wmi Classes if the target computer is running Windows 7 or Windows 2008 R2 Microsoft just might have introduced problems for which they fortunately seem to have a hotfix.

WMI does not allow asynchronous callbacks to a Windows 98 client. The Microsoft Developers Network (MSDN) and TechNet are both good sources of samples. CIM Studio is a tool that enables you to browse WMI Classes on Windows 2000 and later platforms. This documentation is archived and is not being maintained. Wmi Error Invalid Class

Point to Administrative Tools and then click Active Directory Users and Computers. You need to register the MOF file that will add this namespace in to the WMI repository for that product. 47 years ago Reply BigDaddy9z Hey CC, thanks! The following steps describe how to connect to the remote computer and pass WMI queries using the Windows WBEMTEST tool, and you can use it to quickly explore or confirm WMI There’s a registry entry for WMI counters for each service.

WMI Diagnosis Utility TOC Collapse the table of content Expand the table of content This documentation is archived and is not being maintained. Wmi Invalid Namespace Save the following code in a .VBS file and then run the script. http://www.microsoft.com/technet/scriptcenter/guide/default.mspx  The "Tales from the Script" column on TechNetBasic and intermediate scripting topics.

To obtain more information about the source of the problem, you can download and run the WMI Diagnosis Utility diagnostic command line tool.

Add comment Created on Apr 12, 2010 5:01:27 PM by Volker Uffelmann [Paessler Support] Last change on Jan 30, 2014 1:22:24 PM by Gerald Schoch [Paessler Support] Permalink Votes:1 Your Vote: Recent changes to WMI security can also cause this error to occur: Blank passwords, formerly permitted, are not allowed in Windows XP and Windows Server 2003. See ASP.NET Ajax CDN Terms of Use – http://www.asp.net/ajaxlibrary/CDN.ashx. ]]> Server & Tools Blogs > Server & Management Blogs Win32_processor Wmi Invalid Class I've also built on some previous modifications to WMIDiag.vbs to have it successfully run on Windows 8.0 and 8.1 systems.

PA File Sight knows who, and what computer they used. Although available as an administrative option, delegation is typically not recommended because Computer A is providing credentials to Computer B. Windows Management Instrumentation is a core Windows management technology; you can use WMI to manage both local and remote computers. In the Administrative Tools window, double-click Computer Management.

Is there a lesson in that for script writers? The quickest way to do this is via the WMI Control snap-in. NOTE: Working with the registry is for advanced users only. Get a list of applications installed on a local or remote computer.

Q 2. Right-click WMI Control (Local), and then click Properties. It is now reporting correct disk space utilization. WMI Connection based errors - "Connection could not be established" Very often, PRTG is being obstructed from monitoring WMI counters.

To verify availability, look in the Requirements section for each class in the WMI Software Developer Kit (SDK) in the MSDN library (http://msdn.microsoft.com/library/default.asp). Because of that, we encourage you to read the entire document and familiarize yourself with both the things that can go wrong with WMI scripts as well with steps you can By following these recommendations, you can achieve better performance, scalability, reliability, and uptime. For more information, see Debugging Providers, Providing Data to WMI, and Provider Configuration and Troubleshooting Classes.

Though i am able to connect root/cimv2 and parse the result even remotely. 3 years ago Reply Todd When you say make sure you have the latest hotfixes, you mean to To troubleshoot this error, check the namespace security on the remote namespace to see the privileges enabled for the account. 0x80070005 (DCOM ACCESS_DENIED) This error occurs when the connected user is If you are running Windows XP or Windows Server 2003 (and assuming you have the appropriate Administrator rights and have your firewalls configured properly), you should be able to connect to After you familiarize yourself with how the information is categorized, you can easily search for the class you are looking for and find out if the functionality you want is available.

That’s to be expected: after all, the script can’t return the names of the tape drives installed on the computer if there aren’t any tape drives installed on the computer.One way You can manually trust a computer for delegation by doing the following: Click the Start button and then click All Programs. If no appropriate scripting interface is available in the Windows operating system, third-party software might be available that performs the functions you need. Here are two situations that require delegation.

Q 13. Allow WMI through Windows firewall All users (including non-administrators) are able to query/read WMI data on the local computer. Shorter scanning intervals may solve this problem. Since WMI is such an integral part of Windows Operating System, please engage a Microsoft Support Engineer for assistance.